Customization: | Available |
---|---|
Application: | High-performance Transducer, High Frequency Converter Transducer, Soft Starter |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
Overall dimension(mm)
|
|
|
Install dimension(mm)
|
|
|
Drawing
|
||||
|
A
|
C
|
E
|
B
|
D
|
d
|
|
||||
5.5KW-55KW
|
152
|
292
|
215
|
92
|
269
|
M6
|
1
|
||||
75KW-110KW
|
274
|
408
|
260
|
160
|
385
|
M8
|
2
|
||||
132KW-315KW
|
440
|
530
|
290
|
320
|
530
|
M8
|
3
|
Model
|
Star connection method
|
Rated current of delta connection methed
|
SCKR1-7000-5.5-Z
|
11A
|
16A
|
SCKR1-7000-7.5-Z
|
15A
|
22A
|
SCKR1-7000-011-Z
|
23A
|
34A
|
SCKR1-7000-015-Z
|
30A
|
44A
|
SCKR1-7000-018-Z
|
37A
|
55A
|
SCKR1-7000-022-Z
|
45A
|
67A
|
SCKR1-7000-030-Z
|
60A
|
89A
|
SCKR1-7000-037-Z
|
75A
|
111A
|
SCKR1-7000-045-Z
|
90A
|
133A
|
SCKR1-7000-055-Z
|
110A
|
163A
|
SCKR1-7000-075-Z
|
150A
|
222A
|
SCKR1-7000-090-Z
|
180A
|
266A
|
SCKR1-7000-110-Z
|
220A
|
325A
|
SCKR1-7000-132-Z
|
255A
|
377A
|
SCKR1-7000-160-Z
|
320A
|
474A
|
SCKR1-7000-185-Z
|
370A
|
548A
|
SCKR1-7000-200-Z
|
400A
|
592A
|
SCKR1-7000-220-Z
|
425A
|
629A
|
SCKR1-7000-250-Z
|
500A
|
740A
|
SCKR1-7000-280-Z
|
560A
|
829A
|
SCKR1-7000-320-Z
|
630A
|
932A
|
SCKR1-7000-350-Z
|
700A
|
1036A
|
SCKR1-7000-400-Z
|
800A
|
1184A
|
SCKR1-7000-450-Z
|
900A
|
1332A
|
SCKR1-7000-500-Z
|
1000A
|
1480A
|
Application
|
Parameter
|
Suggested Value
|
Centrifugal pump
|
Motor rated current
Starting method
Adaptive starting curve
Start ramp time
Stop mode
Adaptive stop curve
Stop time
|
Depending on model
Adaptive Control
Early acceleration
10 seconds
Adaptive Control
Deceleration
15 seconds
|
Submersible pump
|
Motor rated current
Starting method
Adaptive starting curve
Start ramp time
Stop mode
Adaptive stop curve
Stop time
|
Depending on the model
Adaptive Control
Speed up early
5 seconds
Adaptive Control
After decelerating.
5 seconds
|
Demped fan
|
Motor rated current
Starting method
Current limit
|
Demending on model
Constant current
350%
|
Undamped fan
|
Motor rated current
Starting method
Adaptive starting curve
Start ramp time
Starting limit time
Locked rotor time
|
Depending on model
Adaptive Control
Constant acceleration
20 seconds
30 seconds
20 seconds
|
Screw compressor
|
Motor rated current
Starting method
Start ramp time
Current limit
|
Depending on model
Constant current
5 seconds
400%
|
Reciprocating compressor
|
Motor rated current
Starting method
Start ramp time
Current limit
|
Depending on model
Constant current
5 Second
450%
|
Conveyor belt
|
Motor rated current
Starting method
Start ramp time
Current limit
Stop mode
Adaptive stop curve
Stop time
|
Depending on mode
Constant current
5 seconds
400%
Adaptive Control Constantdeceleration10seconds
|
Conveyor belt
|
Motor rated current
Starting method
Start ramp time
Current limit
Starting limit time
Locked rotor time
|
Depending on mod
Constant current
10 seconds
400%
30 seconds
20 seconds
|
Jaw Crusher
|
Motor rated current
Starting method
Start ramp time
Current limit
Starting limit time
Locked rotor time
|
Depending on model
Constant current
10 second
450%
40 seconds
30 seconds
|
PRODUCT PARAMETERS
|
|
|
||
BRAND
SHCKELE Lectrical
|
MODEL
SCKR1-7000
|
NAME
Soft starter
|
||
TEMPERATURE
25°C~60°C0.
|
LOLTAG
30%~70%UE
|
COMMUNUCATION
RS485 series communication
|
||
CURRENT
1.5~50 e
|
FREQUENCY
≤20TIMES /HOUR
|
VOLTAGE
AC380±15%
|
||
FREQUENCY
50HZ/60HZ
|
STORAGE
45°C~75°C
|
COOLING MODE
Fan cooling
|
||
LANGUAGE
Seven language
|
PROTECTION
IP20
|
HEIGHT
Below 5000 meters above sea level
|