• VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
  • VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
  • VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
  • VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
  • VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
  • VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor

VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor

Application: Fans, Water Pumps, Farm Irrigation, Constant Press
Output Type: Triple
Principle of Work: V/F Control Transducer
Samples:
US$ 68.4/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor pictures & photos
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
US $87.3-671.2 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Relate Products
  • Exhibition
  • Product packaging
  • Certifications
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
SCK200-G3-d75
Switch Mode
High Carrier Frequency PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
AC220V-690V
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
DC24V
Function
Simple Type
Brand
Wce
Input Voltage
220V
Control Mode
Vf/Vector/SVC Control;Panel
Warranty
18 Months
Overload Capacity
1 Minute for 150% ; 10s for 180%; 0.5s for 200%
Nominal Voltage
220V 1phase/380V 3phase
IGBT and DSP
Infineon and Ti
Adaptive Motor
Squirrel-Cage Three-Phase Asynchronous Motor
Power Phase Number
1 Phase to 3 Phase
Type
AC/AC Frequency Converter
Customized
Yes
Cooling Way
Fan
Frequency
0-400Hz Adjustable
Rated Power
0.75 to 55kw
Protection
Over-Current Protection.Overload Protection
Communication
RS485/Modbus
Transport Package
Carton
Specification
Application motor, rectifier bridge, inverter modu
Trademark
WCE
Origin
Zhejiang, China
HS Code
8504409999
Production Capacity
50000pieces/Year

Packaging & Delivery

Package Size
65.50cm * 42.00cm * 48.50cm
Package Gross Weight
38.500kg
Lead Time
3 days (1 - 1 Pieces)
5 days (2 - 10 Pieces)
7 days (11 - 20 Pieces)
To be negotiated ( > 20 Pieces)

Product Description

Product Description
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
 
Inverter SCK200
 
 
 
 
 
Mold
Battery capacity(KVA)
Input Current(A)
Output Current(A)
Power(KW/PH)
 
Single Phase 220V±15% Input Output,50Hz/60Hz
 
 
 
 
 
SCK200G1-d75
1.5
8.2
4
0.75
1
SCK200G1-1d5
3
14
7
1.5
2
SCK200G1-2d2
4
23
9.6
2.2
3
Three phase 220V±15% Input Output,50Hz/60Hz
 
 
 
 
 
SCK200G2-d75
3
5
3.8
0.75
1
SCK200G2-1d5
4
5.8
5.1
1.5
2
SCK200G2-2d2
5.9
10.5
9
2.2
3
SCK200G2-004
8.9
14.6
13
3.7
5
SCK200G2-5d5
17
26
25
5.5
7.5
SCK200G2-7d5
21
35
32
7.5
10
SCK200G2-011
30
46.5
45
11
15
SCK200G2-015
40
62
60
15
20
SCK200G2-018
57
76
75
18.5
25
SCK200G2-022
69
92
91
22
30
SCK200G2-030
85
113
112
30
40
SCK200G2-037
114
157
150
37
50
SCK200G2-045
134
180
176
45
60
SCK200G2-055
160
214
210
55
75
SCK200G2-075
231
307
304
75
100
Three phase 380V±15% Input Output,50Hz/60Hz
 
 
 
 
 
SCK200G3-d75/P3-1d5
1.5
3.4
2.1
0.75
1
SCK200G3-1d5/P3-2d2
3
5
3.8
1.5
2
SCK200G3-2d2/P3-004
4
5.8
5.1
2.2
3
SCK200G3-004/P3-5d5
5.9
10.5
9
4
5
SCK200G3-5d5/P3-7d5
8.9
14.6
13
5.5
7.5
SCK200G3-7d5/P3-011
11
20.5
17
7.5
10
SCK200G3-011/P3-015
17
26
25
11
15
SCK200G3-015/P3-018
21
35
32
15
20
SCK200G3-018/P3-022
24
38.5
37
18.5
25
SCK200G3-022/P3-030
30
46.5
45
22
30
SCK200G3-030/P3-037
40
62
60
30
40
SCK200G3-037/P3-045
57
76
75
37
50
SCK200G3-045/P3-055
69
92
91
45
60
SCK200G3-055/P3-075
85
113
112
55
75
SCK200G3-075/P3-090
114
157
150
75
100
SCK200G3-090/P3-110
134
180
176
90
125
SCK200G3-110/P3-132
160
214
210
110
150
SCK200G3-132/P3-160
192
256
253
132
200
SCK200G3-160/P3-185
231
307
304
160
250
SCK200G3-200/P3-220
250
385
377
200
300
SCK200G3-220/P3-250
280
430
426
220
330
SCK200G3-250/P3-280
355
468
465
250
400
SCK200G3-280/P3-315
396
525
520
280
370
SCK200G3-315/P3-355
455
590
585
315
500
SCK200G3-355/P3-400
500
665
650
355
420
SCK200G3-400/P3-450
565
783
725
400
530
SCK200G3-450/P3-560
630
883
820
450
600
Item
Item
Specifics
Standard
functions
Maximum frquency
vector control:0~300Hz
V/F control:0~3000Hz
 
carrier frequency
0.5-16 kHz (The carrier frequency is automatically adjusted
based on the load features.)
 
Input frequency resolution
Digital setting: 0.01 Hz
Analog setting: maximum frequency x 0.025%
 
Control mode
Sensor-less vector control (SFVC)
Closed-loop vector control (CLVC)+ PG card
Voltage/Frequency (V/F) control
 
Startup torque
G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC)
P type: 0.5 Hz/100%
 
Speed range
1:100 (SFVC)
1:1000(CLVC)
 
Speed stability accuracy
± 0.5% (SFVC) 
± 0.02% (CLVC)
 
Torque control accuracy
± 10% (SFVC)
± 5% (CLVC)
 
Overload capacity
G type: 60s for 150% of the rated current, 3s for 180% of the rated current
P type: 60s for 120% of the rated current, 3s for 150% of the rated current
 
Torque boost
Auto boost
Manual boost 0.1%~30.0%
 
V/F curve
Straight-line V/F curve
Multi-point V/F curve
N-power V/F curve (1.2-power, 1.4-power, 1.6-power,1.8-power, square)
 
V/F separation
Two typescomplete separationhalf separations
 
Acceleration/deceleration curve
Straight-line ramp
S-curve ramp
Four groups of accelerations/deceleration time with the range of 0.0s~65000s
 
DC braking
DC braking frequency0.00Hz~maximum ffrequency
Braking time0.0s~36.0s
Braking trigger current value0.0%~100.0%
Standard
functions
JOG control
JOG frequency range0.00Hz~50.00Hz
JOG acceleration/deceleration time0.00s~6500.0s
 
Built-in simple PLCmultiple speeds
It realizes up to 16 speeds via the sosimple PLC function or combination of DI terminal states
 
Bulit-in PID
It realizes closed loop control system easily
 
Auto voltage regulationAVR
 It can keep constant output voltage automatically when the mains voltage fluctuation.
Standard
functions
Overvoltage/Over current stall control
The current and voltage are limited automatically during the running process so as to avoid frequently tripping due to overvoltage /overcurrent
 
Rapid current limit function
It can auto limit running current of frequency inverter to avoid frequently tripping.
 
Torque limit and control
(Excavator characteristics) It can limit the torque automatically and prevent frequently over current tripping during the running process.
Torque control can be implemented in the mode.
Individualized
functions
High performance
Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology.
 
Instant power off not stop
The load feedback energy compensates the voltage reduction so that the frequency inverter can continue to run for a short time.
 
Rapid current limit
To avoid frequently over current faults of the frequency inverter.
 
Virtual I/O
Five groups of virtual DI/DO can realize simple logic control.
 
Timing control
Time range0.0~6500.0 minutes
 
Multi-motor switchover
Two motors can be switched by two groups of motor parameters.
 
Multiple communication protocols
It supports communication bus via Modbus-RTU, PROIBUS-DP,CANlink and CANopen.
 
Motor overheat protection
The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100,PT1000) so as to realize motor overheat protection
 
Multiple encoder types
It supports various encoders such as differential encoder,open-collector encoder, resolver, UVW encoder, and SIN/COS encoder.
 
Advanced background software
It supports the operation of frequency inverter, by which the state of frequency inverter can be monitored.
RUW
Running command giving
key panel
Control terminals
Serial communication port
You can switch between these giving in various ways.
 
Frequency giving
There are 10 kinds frequency giving digital setting,analog voltage setting, analog setting, pulse setting and serial communication port setting.
You can switch between these giving in various ways.
 
Auxiliary frequency giving
There are 10 kinds auxiliary frequency giving, It can implement tiny tuning of auxiliary frequency and frequency synthesis.
RUN
Input terminal
Standard:
6 digital input(DI)terminals,one of which supports up to 50 kHz high-speed pulse input
2 analog input (AI)terminals,both of them support 0V~10V voltage input or 0mA~20mA current input
Expanding capacity:
many DI terminals
1 AI terminal that supports -10V~10V voltage input.
 
Output terminal
Standard:
1 high- speed pules output terminal (open-collector) that stpports 0-50 kHz square wave signal output
1digital output (DO) terminal
1 relay output terminal
2 analog output (AO) terminals, both of them supports 0mA~20mA current output or 0V~10V voltage output
Expanding  capacity:
many DO terminals
many relay output terminals
Display and
keypad
operation
LED display
It displays the parameters.
 
LCD display
It is optional, supports panel display in Chinese or English language.
 
Key locking and function selection
It can lock the keys partially or completely and define the
function range of some keys so as to prevent misoperation.
 
Protection mode
Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, less voltage protection, overheat protection and overload protection,etc.
Environment
Installation location
Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt.
 
Altitude
Lower than 1000 m
 
Ambient temperature
-10°C~ +40°C (de-rated if the ambient temperature is between 40°C and 50°C)
 
Humidity
Less than 95%RH, without condensing
 
Vibration
Less than 5.9m/s2 (0.6 g)
 
Storage temperature
-20°C ~ +60°C
 
 
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
Relate Products
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
Exhibition
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
Product packaging
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
Certifications
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
Our Advantages
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
FAQ
Can you provide price sheet and catalog to me ?
We are pleasure to provide these to you for reference,you can cotact me,give me your emails ID.

Can you send me a sample?
It's my honor to send a sample to you,but you need to pay the sample fee and shipping cost

What's about your delivery time?
All type we have stock,after we receive payment,we will send you within two days.

How to pay it?
You can pay it to Alibaba,Paypal,bank.

How about your warrantly time?
Our warrantly time is 12months,if the goods or accessories can't work,we send new one to you

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor pictures & photos
VFD Single Phase 220V Input to 3 Phase 380V Output 0.75kw to 55kw for Sewage Pump Motor
US $87.3-671.2 / Piece
Min. Order: 1 Piece
Diamond Member Since 2018

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
65
Year of Establishment
2018-01-23