Customization: | Available |
---|---|
Application: | Fans, Water Pumps, Farm Irrigation, Constant Press |
Output Type: | Triple |
Still deciding? Get samples of US$ 68.4/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Inverter SCK200
|
|
|
|
|
|
|||||
Mold
|
Battery capacity(KVA)
|
Input Current(A)
|
Output Current(A)
|
Power(KW/PH)
|
|
|||||
Single Phase 220V±15% Input Output,50Hz/60Hz
|
|
|
|
|
|
|||||
SCK200G1-d75
|
1.5
|
8.2
|
4
|
0.75
|
1
|
|||||
SCK200G1-1d5
|
3
|
14
|
7
|
1.5
|
2
|
|||||
SCK200G1-2d2
|
4
|
23
|
9.6
|
2.2
|
3
|
|||||
Three phase 220V±15% Input Output,50Hz/60Hz
|
|
|
|
|
|
|||||
SCK200G2-d75
|
3
|
5
|
3.8
|
0.75
|
1
|
|||||
SCK200G2-1d5
|
4
|
5.8
|
5.1
|
1.5
|
2
|
|||||
SCK200G2-2d2
|
5.9
|
10.5
|
9
|
2.2
|
3
|
|||||
SCK200G2-004
|
8.9
|
14.6
|
13
|
3.7
|
5
|
|||||
SCK200G2-5d5
|
17
|
26
|
25
|
5.5
|
7.5
|
|||||
SCK200G2-7d5
|
21
|
35
|
32
|
7.5
|
10
|
|||||
SCK200G2-011
|
30
|
46.5
|
45
|
11
|
15
|
|||||
SCK200G2-015
|
40
|
62
|
60
|
15
|
20
|
|||||
SCK200G2-018
|
57
|
76
|
75
|
18.5
|
25
|
|||||
SCK200G2-022
|
69
|
92
|
91
|
22
|
30
|
|||||
SCK200G2-030
|
85
|
113
|
112
|
30
|
40
|
|||||
SCK200G2-037
|
114
|
157
|
150
|
37
|
50
|
|||||
SCK200G2-045
|
134
|
180
|
176
|
45
|
60
|
|||||
SCK200G2-055
|
160
|
214
|
210
|
55
|
75
|
|||||
SCK200G2-075
|
231
|
307
|
304
|
75
|
100
|
|||||
Three phase 380V±15% Input Output,50Hz/60Hz
|
|
|
|
|
|
|||||
SCK200G3-d75/P3-1d5
|
1.5
|
3.4
|
2.1
|
0.75
|
1
|
|||||
SCK200G3-1d5/P3-2d2
|
3
|
5
|
3.8
|
1.5
|
2
|
|||||
SCK200G3-2d2/P3-004
|
4
|
5.8
|
5.1
|
2.2
|
3
|
|||||
SCK200G3-004/P3-5d5
|
5.9
|
10.5
|
9
|
4
|
5
|
|||||
SCK200G3-5d5/P3-7d5
|
8.9
|
14.6
|
13
|
5.5
|
7.5
|
|||||
SCK200G3-7d5/P3-011
|
11
|
20.5
|
17
|
7.5
|
10
|
|||||
SCK200G3-011/P3-015
|
17
|
26
|
25
|
11
|
15
|
|||||
SCK200G3-015/P3-018
|
21
|
35
|
32
|
15
|
20
|
|||||
SCK200G3-018/P3-022
|
24
|
38.5
|
37
|
18.5
|
25
|
|||||
SCK200G3-022/P3-030
|
30
|
46.5
|
45
|
22
|
30
|
|||||
SCK200G3-030/P3-037
|
40
|
62
|
60
|
30
|
40
|
|||||
SCK200G3-037/P3-045
|
57
|
76
|
75
|
37
|
50
|
|||||
SCK200G3-045/P3-055
|
69
|
92
|
91
|
45
|
60
|
|||||
SCK200G3-055/P3-075
|
85
|
113
|
112
|
55
|
75
|
|||||
SCK200G3-075/P3-090
|
114
|
157
|
150
|
75
|
100
|
|||||
SCK200G3-090/P3-110
|
134
|
180
|
176
|
90
|
125
|
|||||
SCK200G3-110/P3-132
|
160
|
214
|
210
|
110
|
150
|
|||||
SCK200G3-132/P3-160
|
192
|
256
|
253
|
132
|
200
|
|||||
SCK200G3-160/P3-185
|
231
|
307
|
304
|
160
|
250
|
|||||
SCK200G3-200/P3-220
|
250
|
385
|
377
|
200
|
300
|
|||||
SCK200G3-220/P3-250
|
280
|
430
|
426
|
220
|
330
|
|||||
SCK200G3-250/P3-280
|
355
|
468
|
465
|
250
|
400
|
|||||
SCK200G3-280/P3-315
|
396
|
525
|
520
|
280
|
370
|
|||||
SCK200G3-315/P3-355
|
455
|
590
|
585
|
315
|
500
|
|||||
SCK200G3-355/P3-400
|
500
|
665
|
650
|
355
|
420
|
|||||
SCK200G3-400/P3-450
|
565
|
783
|
725
|
400
|
530
|
|||||
SCK200G3-450/P3-560
|
630
|
883
|
820
|
450
|
600
|
Item
|
Item
|
Specifics
|
|
Standard
functions |
Maximum frquency
|
vector control:0~300Hz
V/F control:0~3000Hz
|
|
|
carrier frequency
|
0.5-16 kHz (The carrier frequency is automatically adjusted
based on the load features.)
|
|
|
Input frequency resolution
|
Digital setting: 0.01 Hz
Analog setting: maximum frequency x 0.025%
|
|
|
Control mode
|
Sensor-less vector control (SFVC)
Closed-loop vector control (CLVC)+ PG card
Voltage/Frequency (V/F) control
|
|
|
Startup torque
|
G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC)
P type: 0.5 Hz/100%
|
|
|
Speed range
|
1:100 (SFVC)
1:1000(CLVC)
|
|
|
Speed stability accuracy
|
± 0.5% (SFVC)
± 0.02% (CLVC)
|
|
|
Torque control accuracy
|
± 10% (SFVC)
± 5% (CLVC)
|
|
|
Overload capacity
|
G type: 60s for 150% of the rated current, 3s for 180% of the rated current
P type: 60s for 120% of the rated current, 3s for 150% of the rated current
|
|
|
Torque boost
|
Auto boost
Manual boost 0.1%~30.0%
|
|
|
V/F curve
|
Straight-line V/F curve
Multi-point V/F curve
N-power V/F curve (1.2-power, 1.4-power, 1.6-power,1.8-power, square)
|
|
|
V/F separation
|
Two typescomplete separationhalf separations
|
|
|
Acceleration/deceleration curve
|
Straight-line ramp
S-curve ramp
Four groups of accelerations/deceleration time with the range of 0.0s~65000s
|
|
|
DC braking
|
DC braking frequency0.00Hz~maximum ffrequency
Braking time0.0s~36.0s
Braking trigger current value0.0%~100.0%
|
|
Standard
functions
|
JOG control
|
JOG frequency range0.00Hz~50.00Hz
JOG acceleration/deceleration time0.00s~6500.0s
|
|
|
Built-in simple PLCmultiple speeds
|
It realizes up to 16 speeds via the sosimple PLC function or combination of DI terminal states
|
|
|
Bulit-in PID
|
It realizes closed loop control system easily
|
|
|
Auto voltage regulationAVR
|
It can keep constant output voltage automatically when the mains voltage fluctuation.
|
|
Standard
functions |
Overvoltage/Over current stall control
|
The current and voltage are limited automatically during the running process so as to avoid frequently tripping due to overvoltage /overcurrent
|
|
|
Rapid current limit function
|
It can auto limit running current of frequency inverter to avoid frequently tripping.
|
|
|
Torque limit and control
|
(Excavator characteristics) It can limit the torque automatically and prevent frequently over current tripping during the running process.
Torque control can be implemented in the mode.
|
|
Individualized
functions |
High performance
|
Control of asynchronous motor and synchronous motor are implemented through the high-performance current vector control technology.
|
|
|
Instant power off not stop
|
The load feedback energy compensates the voltage reduction so that the frequency inverter can continue to run for a short time.
|
|
|
Rapid current limit
|
To avoid frequently over current faults of the frequency inverter.
|
|
|
Virtual I/O
|
Five groups of virtual DI/DO can realize simple logic control.
|
|
|
Timing control
|
Time range0.0~6500.0 minutes
|
|
|
Multi-motor switchover
|
Two motors can be switched by two groups of motor parameters.
|
|
|
Multiple communication protocols
|
It supports communication bus via Modbus-RTU, PROIBUS-DP,CANlink and CANopen.
|
|
|
Motor overheat protection
|
The optional I/O extension card enables AI3 to receive the motor temperature sensor input (PT100,PT1000) so as to realize motor overheat protection
|
|
|
Multiple encoder types
|
It supports various encoders such as differential encoder,open-collector encoder, resolver, UVW encoder, and SIN/COS encoder.
|
|
|
Advanced background software
|
It supports the operation of frequency inverter, by which the state of frequency inverter can be monitored.
|
|
RUW
|
Running command giving
|
key panel
Control terminals
Serial communication port
You can switch between these giving in various ways.
|
|
|
Frequency giving
|
There are 10 kinds frequency giving digital setting,analog voltage setting, analog setting, pulse setting and serial communication port setting.
You can switch between these giving in various ways.
|
|
|
Auxiliary frequency giving
|
There are 10 kinds auxiliary frequency giving, It can implement tiny tuning of auxiliary frequency and frequency synthesis.
|
|
RUN
|
Input terminal
|
Standard:
6 digital input(DI)terminals,one of which supports up to 50 kHz high-speed pulse input
2 analog input (AI)terminals,both of them support 0V~10V voltage input or 0mA~20mA current input
Expanding capacity:
many DI terminals
1 AI terminal that supports -10V~10V voltage input.
|
|
|
Output terminal
|
Standard:
1 high- speed pules output terminal (open-collector) that stpports 0-50 kHz square wave signal output
1digital output (DO) terminal
1 relay output terminal
2 analog output (AO) terminals, both of them supports 0mA~20mA current output or 0V~10V voltage output
Expanding capacity:
many DO terminals
many relay output terminals
|
|
Display and
keypad
operation
|
LED display
|
It displays the parameters.
|
|
|
LCD display
|
It is optional, supports panel display in Chinese or English language.
|
|
|
Key locking and function selection
|
It can lock the keys partially or completely and define the
function range of some keys so as to prevent misoperation. |
|
|
Protection mode
|
Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, less voltage protection, overheat protection and overload protection,etc.
|
|
Environment
|
Installation location
|
Indoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt.
|
|
|
Altitude
|
Lower than 1000 m
|
|
|
Ambient temperature
|
-10°C~ +40°C (de-rated if the ambient temperature is between 40°C and 50°C)
|
|
|
Humidity
|
Less than 95%RH, without condensing
|
|
|
Vibration
|
Less than 5.9m/s2 (0.6 g)
|
|
|
Storage temperature
|
-20°C ~ +60°C
|